Sunbury Building
Inspections

The outside walls at a Sunbury handover

Flashings, cappings and clearances: the water details we check before you take the keys.

Sunbury 3429 · 9 April 2026

In short: Inside finishes get the attention at handover, but the outside walls are where water problems start.

Flashings falling the wrong way

We have recorded flashings sloping back toward the house, directing water at the wall instead of away from it.

Cappings with no fall

A wall capping laid flat or back-falling holds water on top, which finds its way into the wall below.

Ground clearances

Weep holes need clearance above paving and cladding needs a gap above concrete. Both were too low on Sunbury handovers.

Control joints and render

Render carried over a control joint stops it moving, which leads to cracking along the joint.

Written by our local inspection team from work carried out in Sunbury. Licensed building practitioners, Building & Plumbing Commission registration CDB-U 53425.

Guides

More pci / handover guides for Sunbury

All guides →

Book a building inspection in Sunbury

Instant online pricing, or talk to the booking team on 1300 471 805.

FAQ

Questions Sunbury owners ask about this

Why do clearances matter?

They keep ground moisture and splashback away from the wall and weep holes.

Can landscaping cause these problems?

Yes. Paving laid later can raise the ground above weep holes, so keep the clearance when you landscape.

Will the builder fix flashings?

They should, when the item is listed in writing before handover.

Is this covered by warranty later?

Generally yes, but fixing it before final payment is much simpler.

CallGet a Free Quote